VF-5
VF-5 GC Columns from Agilent Technologies
Agilent (J&W) VF-5 range of 5% phenylmethyl columns are suitable for a wide variety of applications.
- VF-5ms – inert and low bleed 5% phenyl-methyl phase for increased sensitivity, accuracy, and instrument uptime for semipolar and polar compounds
- VF-5ht – improves the analysis of high boiling compounds by exhibiting low bleed, even at high temperatures
- VF-5 Pesticides – specially designed for the determination of trace levels of pesticide residues
- Rapid-MS –reduce analysis duration by 3 to 5x for temperature programmed, and up to 10x for isothermal runs
All pictures shown are for illustration purpose only. Actual product may vary.
- Buy
- Features
-
VF-5ms GC Columns
Agilent J&W VF-5ms is an inert 5% phenyl-methyl column for increased sensitivity, accuracy and instrument uptime. The column has the lowest guaranteed bleed specification of 1 pA at 325 °C (30 m, 0.25 mm, 0.25 µm). VF-5ms has a slightly higher polarity than the VF-1ms, resulting in a better selectivity for aromatic compounds. This selectivity, combined with superior inertness, also makes these columns applicable for a wide range of semipolar and even polar components, such as phenols.- Highly inert 5% phenylmethyl column for increased sensitivity, accuracy and instrument uptime
- Minimal column bleed improves sensitivity – ultra low bleed specification of 1 pA @ 325 °C (30 m x 0.25 mm, 0.25 μm)
- Slightly higher polarity than VF-1ms, results in improved selectivity for aromatic compounds; selectivity and excellent inertness make these columns applicable for a wide range of semi-polar and even polar compounds
- 0.15 mm id columns available for high efficiency GC and GC/MS analyses
- QC test results for retention index, efficiency, selectivity and bleed is reported with every column
- Supplied with EZ-GRIP to simplify column installation, coupling and operation
Similar Phases: Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, PTE-5, BPX-5, AT-5ms, ZB-5ms, ZB-5MSi, SLB-5ms, Equity-5
VF-5ht GC Columns
Agilent J&W VF-5ht improves the analysis of high boiling compounds with low-bleed performance, even at high temperatures. Based on ultra-low-bleed technology, VF-5ht provides unmatched selectivity, sensitivity, and accuracy for the analysis of high molecular weight compounds. Temperature limits -60 to 400 °C for fused silica and -60 to 450°C for Ultimetal stainless steel.- Enhanced stability improves column longevity and reduces downtime
- Superior detector performance provides improved detection limits
- For analyses of high boiling compounds by exhibiting ultra low bleed at high temperatures
- Optimized sensitivity and accuracy for analysis of high molecular weight compounds
- Identical selectivity as VF-5ms (bleed spec of 30 m x 0.25 mm column is < 5 pA at 400 °C)
- UltiMetal technology renders the stainless steel inert and enhances bonding of the stationary phase for improved column lifetime and excellent peak shape
Similar Phases: ZB-5ht, Rxi-5ht
VF-5 Pesticides Columns
Agilent J&W VF-5 Pesticides columns are specially designed for the determination of trace levels of pesticide residue. Every column is individually tested before shipment with key pesticides, including endrin and aldrin, ensuring optimal performance and consistency of results.- Specially designed for the determination of trace levels of pesticide residue
- Highly inert for enhanced ECD and MS detection
- Tested with key pesticides including endrin and aldrin for optimal performance and consistency of results
- Low bleed
Rapid-MS GC Columns
Agilent J&W Rapid-MS columns reduce analysis duration by three to five times for temperature programmed, and up to a 10 times for isothermal runs. The film thickness from 0.1 to 1 µm ensures high loadability and the higher sensitivity typically increases the signal-to-noise ratio by a factor of three or greater.- Equivalent to 5% phenyl, 95% dimethylpolysiloxane
- Fast analysis time improves productivity
- Reduce analysis time by 3-5x for temperature programmed, and up to a 10x for isothermal runs
- The film thickness from 0.1 to 1 μm ensures high loadability and higher sensitivity
- Low bleed
- Rapid-MS columns utilize the high optimal carrier gas velocity obtained when a separation is performed under reduced pressure for fast analysis times
- Specifications
-
VF-5ms Temperature Specifications
ID (mm) 0.10 mm 0.15 – 0.32 mm 0.53 mm Length (m) 10 – 20 m 10 – 60 m 15 – 30 m Film (µm) 0.40 µm 0.15 – 1.00 µm 0.50 – 1.50 µm Temperature Limits (°C) -60 – 325/350 °C -60 – 325/350 °C -60 – 325/350 °C
-60 – 310/335 °C (1.50 µm)VF-5ht Temperature Specifications
ID (mm) 0.25 - 0.32 mm Length (m) 10 - 30 m Film (µm) 0.10 µm Temperature Limits (°C) -60 -400 °C VF-5 Pesticides Temperature Specifications
ID (mm) 0.25 - 0.32 mm Length (m) 30 - 50 m Film (µm) 0.25 µm Temperature Limits (°C) -60 -325/350 °C Rapid-MS Temperature Specifications
ID (mm) 0.53 mm Length (m) 10 m Film (µm) 0.12 - 0.50 µm Temperature Limits (°C) -60 to 325/325 °C - Literature
-
-
AGILENT GC COLUMN BROCHURE
Full range of GC Columns and Applications
-
- Videos
-
-
Agilent GC Column Installation Video GC Troubleshooting Series
-
Agilent Leak Check for GC GC Troubleshooting Series
-